Isolation amplifier

 

  • Galvanically separated input, output, and supply
  • Bipolar current / voltage input
  • Signal conversion
  • Current and voltage output
  • 24 VDC supply or universally supplied
  • Applicable in PELV/SELV circuits
  1. Overview

  2. Technical details

  3. Accessories


Advanced features

  • Programmable input and output ranges using internal DIP-switches.
  • Front panel fine adjustment of 0 and 100% values for special ranges.

Application

  • Galvanic separation of analog signals.
  • Measurement of floating signals.

Technical characteristics

  • Analog signal conditioning with microprocessor based gain and zero offset with a fast response time of less than 25 ms.
  • Signal conversion within the ranges: -250...+250 VDC or -50...+50 mA on the input and 0...10 (20) VDC and 0...20 mA on the output.
  • Galvanically separated between input, supply, and output.
  • 2-wire transmitter supply and a reference voltage of 2.5 VDC, max. 15 mA for short circuit-protected supply of potentiometers.
  • Buffered voltage output 0...20 V, 10 mA.
  • The output can be ordered for standard 0/4...20 mA, and 0/1...5mA or special currents and selectable voltages within the signal range 0...1 VDC or and ranges 0...10 VDC.
  • Output signal reversal.
  • Mounting for a standard 11-pole socket which can be adapted for DIN rail or plate use with PR’s 7023 adaptor and 7024 mounting keying.

Environmental Conditions

Operating temperature -20°C to +60°C
Calibration temperature 20...28°C
Relative humidity < 95% RH (non-cond.)
Protection degree IP50

Mechanical specifications

Dimensions (HxWxD) 80.5 x 35.5 x 84.5 mm (D is without pins)
Weight DC / universally supplied 125 g / 165 g

Common specifications

Supply

Supply voltage 19.2...31.2 VDC
Supply voltage, universal 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC
Max. required power ≤ 2.4 W (2284--D) ≤ 2.5 W (2284--P)

Isolation voltage

Isolation voltage, test / working 3.75 kVAC / 250 VAC
PELV/SELV IEC 61140

Response time

Response time (0...90%) < 25 ms
Signal / noise ratio Min. 60 dB
Effect of supply voltage change < 0.005% of span / VDC
2-wire transmitter supply (pin 7...5) 19...28 VDC / 20...0 mA
Auxiliary voltages: Reference voltage 2.5 VDC ±0.5% / 15 mA
Temperature coefficient < ±0.01% of span / °C
Linearity error < 0.1% of span
EMC immunity influence < ±0.5% of span

Input specifications

Common input specifications

Max. offset 50% of max. value

Current input

Measurement range -50...+50 mADC
Min. measurement range (span) 0.53 mADC
Input resistance Nom. 50 Ω

Voltage input

Measurement range -250...+250 VDC
Min. measurement range (span) 27 mVDC
Input resistance >1 MΩ...<10 MΩ

Output specifications

Current output

Signal range 0...20 mA
Min. signal range 4 mA
Load (@ current output) ≤ 1000 Ω
Load stability ≤ 0.01% of span / 100 Ω
Current limit 23...28 mA
Voltage output through internal shunt See manual for details

Observed authority requirements

EMC 2014/30/EU
LVD 2014/35/EU
EAC TR-CU 020/2011
Ihre Anfrage wurde erfolgreich versendet - 0 Artikel in Ihrer Liste
Produktbeschreibung Stückzahl
Bitte spezifizieren Sie eine Variante (siehe Datenblatt) – oder wählen Sie „Variante unbekannt“
Ihre Kontaktdaten
Weitersuchen
Keine Artikel ausgewählt….
Es befinden sich keine Artikel in Ihrer Liste…

Von den produktbezogenen Seiten auf unserer Homepage können Artikel zu der Liste hinzugefügt und uns diese Liste zugeschickt werden. Hierdurch wird ein Angebot eingeholt. Sie fügen Artikel zu Ihrer Liste hinzu, indem Sie auf der individuellen Produktseite das Feld “Anfrage stellen” anklicken.

Sobald uns die Liste zugeschickt wurde, werden wir uns schnellstmöglich mit Ihnen in Verbindung setzen.

Sollte uns die Liste nicht zugeschickt werden, so steht Sie Ihnen für eine Dauer von 7 Tagen zur Verfügung (Dies ermöglicht die Cookie-Technik auf Ihrem PC bzw. Tablet)
Wir hoffen, dass Ihnen diese Funktion nützlich ist. Bitte fügen Sie Artikel über die Produkt-Seiten zur Liste hinzu.
Vielen Dank für Ihre Anfrage.
Wir werden uns schnellstmöglich per Telefon oder per E-Mail mit Ihnen in Verbindung setzen.